2022 October 07 19:00 | User Capacity: 240 057 409 536 bytes [240 GB]



SMART overall-health self-assessment test result: PASSED
          9 Power_On_Hours          0x0012   100   100   000    Old_age   Always       -       18222
        
smartctl 6.6 2016-05-31 r4324 [i686-linux-4.15.0-192-generic] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: Patriot Blast Serial Number: Hidden Firmware Version: SAFM12.2 User Capacity: 240 057 409 536 bytes [240 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-2 (minor revision not indicated) SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Fri Oct 7 21:00:02 2022 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 30) seconds. Offline data collection capabilities: (0x79) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 2) minutes. Conveyance self-test routine recommended polling time: ( 3) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0/0 9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 18222 12 Power_Cycle_Count 0x0012 100 100 000 Old_age Always - 638 168 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 0 170 Unknown_Attribute 0x0003 100 100 010 Pre-fail Always - 150 173 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 5439602 192 Power-Off_Retract_Count 0x0012 100 100 000 Old_age Always - 208 194 Temperature_Celsius 0x0023 070 070 030 Pre-fail Always - 30 (Min/Max 30/30) 218 Unknown_Attribute 0x000b 100 100 050 Pre-fail Always - 0 231 Temperature_Celsius 0x0013 100 100 000 Pre-fail Always - 17 241 Total_LBAs_Written 0x0012 100 100 000 Old_age Always - 38078 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error 1 Short offline Completed without error 00% 18213 - 2 Short offline Completed without error 00% 18201 - 3 Short offline Completed without error 00% 18189 - 4 Short offline Completed without error 00% 18177 - 5 Short offline Completed without error 00% 18165 - 6 Short offline Completed without error 00% 18153 - 7 Short offline Completed without error 00% 18141 - 8 Short offline Completed without error 00% 18129 - 9 Short offline Completed without error 00% 18117 - 10 Short offline Completed without error 00% 18105 - 11 Short offline Completed without error 00% 18093 - 12 Short offline Completed without error 00% 18081 - 13 Short offline Completed without error 00% 18069 - 14 Short offline Completed without error 00% 18057 - 15 Short offline Completed without error 00% 18045 - 16 Short offline Completed without error 00% 18033 - 17 Short offline Completed without error 00% 18021 - 18 Short offline Completed without error 00% 18009 - 19 Short offline Completed without error 00% 17997 - 20 Short offline Completed without error 00% 17985 - 21 Short offline Completed without error 00% 17973 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.