2022 July 24 16:51 | User Capacity: 4,000,787,030,016 bytes [4.00 TB]



SMART overall-health self-assessment test result: PASSED
          9 Power_On_Hours          0x0032   001   001   000    Old_age   Always       -       49605
        196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       -       0
        197 Current_Pending_Sector  0x0032   100   100   000    Old_age   Always       -       0
        198 Offline_Uncorrectable   0x0030   100   100   000    Old_age   Offline      -       0
        
smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.4.0-122-generic] (local build) Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: TOSHIBA MC04ACA400E Serial Number: Hidden LU WWN Device Id: 5 000039 74ba000db Firmware Version: FP2A User Capacity: 4,000,787,030,016 bytes [4.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Form Factor: 3.5 inches Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ATA8-ACS (minor revision not indicated) SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Sun Jul 24 16:51:31 2022 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 120) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 485) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0/0 2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline - 0 3 Spin_Up_Time 0x0027 100 100 001 Pre-fail Always - 6161 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 28 5 Reallocated_Sector_Ct 0x0033 100 100 050 Pre-fail Always - 0 7 Seek_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0/0 8 Seek_Time_Performance 0x0005 100 100 050 Pre-fail Offline - 0 9 Power_On_Hours 0x0032 001 001 000 Old_age Always - 49605 10 Spin_Retry_Count 0x0033 100 100 030 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 28 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 1215 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 26 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 140 194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 35 (Min/Max 25/50) 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0 220 Disk_Shift 0x0002 100 100 000 Old_age Always - 0 222 Loaded_Hours 0x0032 001 001 000 Old_age Always - 49420 223 Load_Retry_Count 0x0032 100 100 000 Old_age Always - 0 224 Load_Friction 0x0022 100 100 000 Old_age Always - 0 226 Load-in_Time 0x0026 100 100 000 Old_age Always - 563 240 Head_Flying_Hours 0x0001 100 100 001 Pre-fail Offline - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error 1 Short offline Completed without error 00% 48904 - 2 Short offline Completed without error 00% 48892 - 3 Short offline Completed without error 00% 48880 - 4 Short offline Completed without error 00% 48868 - 5 Short offline Completed without error 00% 48856 - 6 Short offline Completed without error 00% 48844 - 7 Short offline Completed without error 00% 48832 - 8 Short offline Completed without error 00% 48820 - 9 Short offline Completed without error 00% 48808 - 10 Short offline Completed without error 00% 48796 - 11 Short offline Completed without error 00% 48784 - 12 Short offline Completed without error 00% 48772 - 13 Short offline Completed without error 00% 48760 - 14 Short offline Completed without error 00% 48748 - 15 Short offline Completed without error 00% 48736 - 16 Short offline Completed without error 00% 48724 - 17 Short offline Completed without error 00% 48712 - 18 Short offline Completed without error 00% 48700 - 19 Short offline Completed without error 00% 48688 - 20 Short offline Completed without error 00% 48676 - 21 Short offline Completed without error 00% 48664 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.